Maybe many people ever heard about the CFB anti-wear beams technology , now this technology has been updated into new generation anti wear technology -----Wuhan Yongping Grille Anti-wear Technology . The Grille anti wear technology now can eradicate the CFB tubes abrasion completly , so far there are more than 200 CFB boilers all over the world ever used this technology and this technology can prevent the tubes leaking at least 5 years , according to the situations of the CFB boilers used the grille anti wear technologies .
Here we will introduce the technology changes history about the CFB tubes anti abrasion development . Circulating fluidized bed boiler furnace process determines that there is a "ring-core" flow structure in the furnace, in the center of the furnace gas upward movement, around the wall flow downward flow, and the downward flow rate is increasing. In the process of flowing downward to the wall, the water wall has been seriously eroded for a long time. For the CFB boiler burning high ash and poor quality coal, the problem of water wall wear is more prominent.
In the early stage of CFB boiler, the abrasion-proof measures such as tube release, anti-abrasion bump, anti-abrasion protective tile and metal spraying can slow down the abrasion rate of water-wall to a certain extent, but it is difficult to solve the problem of water-wall abrasion thoroughly.
_active multi-stage anti-wear device reduces the concentration and velocity of wall-adherent flow step by step. The anti-wear device can effectively reduce the wear of water wall and prolong its service life. Within one year of operation, 30-50 points were randomly selected from the CFB boiler water wall tubes (bottom-up basically uniform), the thickness of tube wall thinning at 100% sampling points was less than 0.6 mm, and the thickness of tube wall thinning at 80% sampling points was less than 0.4 mm. The anti-abrasion device not only improves the operation economy of power enterprises, but also provides reliable protection against abrasion of water wall for CFB boilers burning inferior coal fuel.
Technology innovation
_(1) Adopting active anti-wear device, the adherent flow changes the flow direction when it meets the anti-wear device, and accelerates the flow downward instead of moving toward the center of the furnace, which obviously reduces the adherent flow concentration and reduces the wear of the water wall of CFB boiler;
_(2) Adopting multi-stage anti-wear structure, the wall-adherent flow is divided into several sections, which can obviously reduce the velocity of wall-adherent flow and reduce the wear of water-wall of CFB boiler;
_(3) Adopt trapezoidal anti-wear structure to avoid local eddy current wear at the junction of anti-wear device and water wall;
_(4) The anti-wear device is arranged in the way of "upper dilution and lower density". It not only effectively realizes the anti-wear of the water wall of CFB boiler, but also realizes that the anti-wear device has little effect on the heat transfer coefficient and ensures the heat absorption of the water wall. It
Principle explanation
It is generally believed that the wear rate of water wall is closely related to the flow velocity, particle size, material concentration and the inhomogeneity of flow field. The specific relationship is as follows: E = kWaD2U_.
The wear rate: (m/100h)
The coefficient of proportionality (-)
Material velocity (m/s)
Speed index (3 to 3.5)
Particle size (mm)
Material concentration (kg/ (M2? S))
From the above formula, it can be seen that the wear rate of wall-to-wall flow is proportional to the 3-3.5 power of the flow rate of wall-to-wall materials. From the point of view of reducing the velocity and concentration of wall-to-wall flow around the wall, the active anti-wear device of water wall adopts multi-stage arrangement. Fig. 1 is a schematic diagram of the anti abrasion mechanism of the CFB water wall active anti abrasion device.
Such
Fig. 1CFB schematic diagram of the anti abrasion mechanism of the boiler water wall active anti abrasion device
Application performance
By the end of 2011, 39 300 MWCFB boiler units had successfully installed active water wall anti-wear devices, exceeding 3/4 of the 300 MWCFB boilers that have been put into operation. The operation of the boiler after installing the water wall active anti-wear device shows that the installation of the anti-wear device has little effect on the main operation parameters of CFB boiler.
It
Name of power plant
Unit capacity
Boiler factory
install date
Name of power plant
Unit capacity
Boiler factory
install date
Henan Pingdingshan Rui Ping Coal Co., Ltd.
2 x 480t/h
Dongfang Boiler Works
2006.12 (#1)
2007.02 (#2)
Datang Honghe Power Plant
2 x 1025t/h
hbc
Two thousand and eight point zero eight
Shanxi Jinneng group Datong thermoelectric Co., Ltd.
2 x 480t/h
hbc
Two thousand and seven point five
China's West Lai Feng power plant
2 x 690t/h
Dongfang Boiler Works
Two thousand and nine point one two
Tianjin Chen Tang Thermal Power Co., Ltd.
1 x 440t/h
hbc
Two thousand and seven point seven
Shenhua Shendong Electric Power Co., Ltd.
4 300MWCFB boilers
Two thousand and nine point one two
Henan Zhongfu Electric Power Co., Ltd. two branch company
1 x 440t/h
Shanghai Boiler Works
Two thousand and seven point one two
Tengzhou low calorific value Thermal Power Co., Ltd.
Ji'nan Boiler Works
2 x 240t/h
Two thousand and ten point four
Erdos Double Power Generation Co., Ltd.
2 x 440t/h
Ji'nan Boiler Works
Two thousand and eight point zero three
Zaozhuang south suburb thermoelectric Co., Ltd.
hbc
2 x 240t/h
Two thousand and ten point seven
Wuhai Jun Zheng Energy Chemical Co., Ltd.
1 x 470 t/h
Dongfang Boiler Works
Two thousand and eight point zero five
Guizhou Huadian Bijie Thermal Power Co., Ltd.
Dongfang Boiler Works
2 x 490t/h
Two thousand and ten point seven
Henan Luoyang sunshine thermal power plant
1 x 440 t/h
Dongfang Boiler Works
Two thousand and eight point zero nine
Shenhua Coal Oil Co., Ltd.
Wuxi Boiler Works
3 x 410/h
Two thousand and ten point four
Ningbo Sinopec Zhenhai Refining and chemical branch company
1 x 450 t/h
FOSTER WHEELER
Two thousand and eight point one one
Huaneng suer thermoelectric Co., Ltd.
Shanghai Boiler Works
2 x 240t/h
Two thousand and ten point three
Huadian Wuda Power Generation Co., Ltd.
2 x 480 t/h
Dongfang Boiler Works
2008.05 (#1)
2008.10 (#2)
Huaibei Lihuan Zhongli Power Generation Co., Ltd. two phase
hbc
2 x 1100t/h
Two thousand and ten
Qinhuangdao Qin Heat Power Co., Ltd.
2 x 1025t/h
Dongfang Boiler Works
2008.05 (#5)
2008.10 (#6)
Fujian Huadian Zhangping Thermal Power Co., Ltd.
Dongfang Boiler Works
2 x 1025t/h
Two thousand and ten point nine
Huaibei Lihuan Zhongli Power Generation Co., Ltd.
2 x 1025t/h
hbc
Two thousand and eight point zero four
Fujian Huadian Yongan Power Generation Co., Ltd.
Dongfang Boiler Works
2 x 1025t/h
Two thousand and ten point one one
Guodian Kaiyuan Power Generation Co., Ltd.
2 x 1025t/h
Shanghai Boiler Works
Two thousand and eight point zero six
Two thousand and nine point zero eight
With coal power Wang Ping Power Generation Co., Ltd.
2 x 725t/h
Huaxi boiler factory
Two thousand and eleven point nine
Guangdong Bao Li Hua power Co., Ltd.
2 x 1025t/h
Dongfang Boiler Works
Two thousand and eight point zero nine
Huadian Sujiatun Thermal Power Co., Ltd.
2 x 670t/h
Wuxi boiler
Please feel free to contact me!
Please contact us for more information+86-18062456085